Movable holder for a quartz crystal microbalance for exact growth rates in pulsed laser deposition

Controlling the amount of material deposited by pulsed laser deposition (PLD) to a fraction of one atomic layer is very important for nanotechnology based thin film heterostructures. Though incomparable to measure the growth rate with high accuracy, which weighed quartz crystals (QCM) suffers from several limitations when applied to PLD. Strong directionality of the PLD plasma plume and a clear dependence on the deposition parameters (for example, the background pressure and Fluence) requires that QCM is placed in the same position as substrate for growth. However, the QCM sensor is generally fixed to one side of the substrate. It also requires the rapid degradation of the crystal, as it is constantly exposed to the ablated material. Design for QCM holder moves are discussed in this work to overcome this problem. holder is compatible with standard transfer arm, allowing easy insertion and transfers between PLD room and the room next to other vacuum. QCM can be placed in the same position as substrate for the growth of PLD. the resonance frequency was measured in a vacuum in any location where it can be in contact with the electrical feedthrough, before and after deposition. We tested the design for the deposition of hematite (Fe2O3), comparing the level derived from QCM and of reflection high-energy electron diffraction oscillations during homoepitaxial growth.

neptunium electrochemical precipitation by electrochemical quartz crystal micro weighed

microliter volume used in the electrochemical detection and preconcentration of radionuclides to reduce the dose received by researchers and equipment. Unfortunately, there is no shortage of radionuclide analysis coupled with electrochemical techniques and reactor microliter volume. The aim of this work is 1) to develop a micro-miniature electrochemical quartz crystal weighed (μeQCM) reactor for use in a small volume (50-200 uL) electrogravimetric experiment and 2) using it to characterize preconcentration reactor at neptunium on carbon electrode through electroprecipitation. We successfully saved neptunium in new and verified μeQCM reactor operations. We found that the preconcentration of neptunium in coated carbon electrodes is possible by chronoamperometry at -1.6 VAG / AgCl. The resulting precipitate mass shift is indicative of the amount of neptunium in the electrode, although the correlation between the increase in mass and activity of preconcentrated material is not linear. Neptunium precipitate reduced electron transfer to the solution as evidenced by an increase in charge transfer resistance compared with bare electrodes.